Simrad TRANSDUCER - INSTALLATION GENERIC REV H Manuale di Installazione Pagina 139

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 212
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 138
Cablelayoutandinterconnections
PowerSupplyUnitwiring
ThreePowerSupplyUnitsareused,oneforeachTRXUtransceiverrack.Thecablesare
terminatedatterminalblocks;oneinsideeachPowerSupplyUnit,andoneoftherear
sideofeachTRXUrack.FromtheterminalblockontherearsideofeachTRXU,three
DCcablebundlesarefeduptotherearsideoftherackandterminatedwithplugson
thePowerConnectorPanel.TheACpowerprovidedbythePowerSupplyUnitsisalso
terminatedonthePowerConnectorPanel,anditisonlyusedtopowertheTRXUfans.
Allpowercables(ACandDC)areprovidedwiththePowerSupplyUnits.Maximum
cablelengthbetweeneachPowerSupplyUnitandtheTransceiverUnitis10meters.
PowerSupplyUnitsACmainswiring
TheACmainscablesforthethreePowerSupplyUnitsareconnectedtoTerminalBoard
1insideeachcabinet.
W246A
RevA
Powercabinets, ACinput
9
10
11
230Vac
230Vac
Ground
Terminalboard
inPowerCabinet
230Vac
input
ThePowerCabinetsisprovidedwithan ACmainscablereadilyconnectedtotheterminalboard.
Cablespecications
Conductors:2.5mm²
Screen:Separateconductor
Voltage:600V
Maximumdiameter:Limitedbythegrommetsonthecabinet
331549/B