Simrad TRANSDUCER - INSTALLATION GENERIC REV H Manuale di Installazione Pagina 110

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 212
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 109
SimradMS70
[R]Powercablestoship’s230Vacmainssupply
ThepowercablesprovidedtosupplytheTransceiverUnitwith230V acmainsare
connectedtothefourcircuitbreakersinthebottomoftherack.
Circuitbreakers
CircuitBreaker0(left):FeedsDistributor0(bottom),forfutureexpansions
CircuitBreaker1:FeedsDistributor1(middle),powersTRCbeamformingcomputers
0,1and2
CircuitBreaker2:FeedsDistributor2(top),powersTRCbeamformingcomputers3,4
and5andtheEthernetSwitch
CircuitBreaker3(right):Feedsthemainfanunitatthebottomoftherack
Theotherendofthemainscablesarettedwithastandardmainsplug.
Table8Powercablestoship’ smains
Cable
FromTo
R1
Ship’smainssupplyCircuitbreaker0
R2
Ship’smainssupplyCircuitbreaker1
R3
Ship’smainssupplyCircuitbreaker2
R4
Ship’smainssupplyCircuitbreaker3
AllcablesareprovidedbyKongsbergMaritime.
Relatedtopics
Powercables;TransceiverUnitonpage88
Circuitbreakeronpage146
108
331549/B
Vedere la pagina 109
1 2 ... 105 106 107 108 109 110 111 112 113 114 115 ... 211 212

Commenti su questo manuale

Nessun commento