On-boardmaintenance
Figure57LocationofS301andS302intheMotorControl
Unit
HOIST STOP
REMOTE LOWER
(CD015409-033)
S301
S302
3Observethatthetransducerislowered.
Thehoistingmotorwillautomaticallystopwhenthe
transducershaftreachesthelowerlimitswitch,butyoucan
stoptheloweringearlierbyswitchingS302topositionSTOP.
4Setthehoist/lowerswitchS302topositionSTOP.
5ReleasethemotorprotectingswitchS301bypressingits
handledowntopositionOFF.
6PlacealabelontheMotorControlUnittoinformother
personnelthatthetransducerhasbeenloweredfor
maintenancepurposes.
7Performathoroughcheckofthetransducer.Ifnecessary,
cleanit.
1Tocleanthetransducer,usenormalsyntheticsoapand
water.
2Toremovemarinegrowth,usene-gradesandpaper
oremerypaper.
3D
o n o t usestrongsolvents.
4D
o n o t attempttoscrapeofmarinegrowthwithsheets
ofmetal,screwdriversorothermetallictools.
5D
o n o t usehighpressurewatertocleanthetransducer.
8ActivatethemotorprotectingswitchS301bypressingthe
handletopositionUP .
9Setthehoist/lowerswitchS302topositionHOIST.
323775/B