The ITI system has four (female) serial ports, A, B C and D. All
message transferred via these serial lines are based on the NMEA
0183 format protocol.
A
B
C
D
ETHERNET REMOTE CONTROL MONITOR
CENTRO N IX
TD-L TD-R
230 V mains supply
Gyro-compass,
l og, etc.
(Cd4346)
Port A, C and D have the following dedicated functions:
• Port A for connection to an echo sounder
• Port C to a sonar
• Port D to a navigator.
Port B is dedicated for:
• Auxiliary equipment like Winch control system, Track plotter,
data logger etc.
If port C is not used by the sonar the port might be used for optional
output of the Trawl position (GLL) to an auxiliary plotter. Port A,
B and C have two-way communication while port Donly has input
data. All four serial lines can receive telegrams without being
activated from the menu.
Ports A, B and C must be activated from the menu before any
messages being transmitted.
Transmitted messages
A NMEA telegram will be transmitted when its data has been
updated. Each individual parame ter a vailable on the serial line B
(AUX) can be turned ON or OFF from the menu.
Individual parameters can not be set ON or OFF on serial lines A
and C. These two serial lines have been allocated for interfacing
to Echo sounder and Sonar respectively, and all parameters on any
of these two lines are either activated or not activated.
No parameters are transmitted out on serial port D.