Sommario

Pagina 1 - Operator manual

Simrad SH80High frequency fishery sonarOperator manualM A X I M I Z I N G Y O U R P E R F O R M A N C E A T S E Awww.simrad.com

Pagina 2

Simrad SH80VI850-164385 / Rev.CON-BOARD MAINTENANCE 150...Introduction 150...

Pagina 3 - High frequency fishery sonar

Simrad SH8090850-164385 / Rev.CBearing (Display)The Bearing button is located in the Display menu.This is simply a selector switch. Click on the butto

Pagina 4 - About this document

Parameters91850-164385 / Rev.CBearing (Vertical)The Bearing (Vertical) parameter is accessed from the Verticalmenu.This dialogue allows you to train t

Pagina 5 - Sections

Simrad SH8092850-164385 / Rev.CColour ThresholdThe Colour Threshold button is located on the Display menu.The Colour Threshold function is used to red

Pagina 6

Parameters93850-164385 / Rev.CColoursThe Colours button is located in the Display menu.The colour strength of the echo presentation can be selected wi

Pagina 7

Simrad SH8094850-164385 / Rev.CData SourceThe Data Source button is located in the Vertical View menu.The Vertical View menu is are activated by press

Pagina 8

Parameters95850-164385 / Rev.CDead ReckoningDead Reckoning is accessed from the Setup menu.Dead Reckoning is used to improve the position of the histo

Pagina 9

Simrad SH8096850-164385 / Rev.CDefault SettingDefault Setting is accessed from the Setup menu.This function makes it possible to delete all the parame

Pagina 10 - 850-164385 / Rev.C

Parameters97850-164385 / Rev.CDirection IndicatorThe Direction Indicator is accessed from the Vertical Viewmenu when Data Source is set to Indicator.T

Pagina 11 - SYSTEM DESCRIPTION

Simrad SH8098850-164385 / Rev.CEdit Gear (Purse)The Gear parameter dialogue is accessed on the Setup menu.Each of the available options in the Gear di

Pagina 12 - System overview

Parameters99850-164385 / Rev.CEdit Gear (Trawl)The Gear parameter dialogue is accessed on the Setup menu.Each of the available options in the Gear dia

Pagina 13 - Sonar room units

System description1850-164385 / Rev.CSYSTEM DESCRIPTIONIntroductionThe Simrad SH80 sonar is an omnidirectional high frequencysonar, designed for all s

Pagina 14 - System diagram

Simrad SH80100850-164385 / Rev.CWidthA dedicated parameter dialogue is provided to define the widthof the trawl opening. The setting is made automatic

Pagina 15 - System description

Parameters101850-164385 / Rev.CEdit SchoolThe Edit School parameter dialogue is accessed from theSchool buttonintheSetup menu. In the School dialogue,

Pagina 16 - Scientific output

Simrad SH80102850-164385 / Rev.CExternal SynchronizationThe External Sync button is located in the Setup menu.The External synchronization function ma

Pagina 17 - Functional description

Parameters103850-164385 / Rev.CFish AlarmThe Fish Alarm button is located in the Setup menu.The Fish Alarm function makes it possible to set up theson

Pagina 18

Simrad SH80104850-164385 / Rev.CFrequencyThe Frequency parameters can be called from the Horizontaland Vertical menus.Note that this parameter dialogu

Pagina 19 - Reception

Parameters105850-164385 / Rev.CGainThe Gain is accessed from the Horizontal and Vertical menus.The Gain is normally selected from the Sonar Operating

Pagina 20 - Transmission

Simrad SH80106850-164385 / Rev.CGearThe Gear button is located in the Setup menu.The Gear parameter dialogue is used to select the type of fishinggear

Pagina 21 - → Frequency options, page 6

Parameters107850-164385 / Rev.CHeadingThe Heading parameter is accessed by pressing the Hdg(Heading) button in the Status dialogue at the bottom of th

Pagina 22 - Peripheral equipment

Simrad SH80108850-164385 / Rev.CInspect ObjectThe Inspect Object parameters are either accessed when youselect a target marker in the Objects menu, or

Pagina 23 - DISPLAY MODES

Parameters109850-164385 / Rev.CLanguageThe Language button is located on the Display menu.The Language parameter dialogue is used to select the langua

Pagina 24 -  Cosmetics, page 50

Simrad SH802850-164385 / Rev.CSystem overviewMain unitsThe Simrad SH80 sonar consists of the following units: Wheelhouse units:- Display monitor- Son

Pagina 25 - North Up

Simrad SH80110850-164385 / Rev.CMenuThe Menu button is located in the Display menu.The Menu parameter is used to select different levels ofcomplexity

Pagina 26 - True Motion

Parameters111850-164385 / Rev.CMessage BarThe Message Bar button is located in the System test menu.This menu is accessed by pressing the Test... butt

Pagina 27 - 180°/Audio

Simrad SH80112850-164385 / Rev.CModeThe Mode button is located on the top of every menu.The Mode parameter dialogue is used to select display mode. It

Pagina 28 - 270°/Vertical

Parameters113850-164385 / Rev.CMode ButtonsThe Mode Buttons button is located in the Display menu.This is simply a selector switch. Click on the butto

Pagina 29 - Bow Up / Vertical

Simrad SH80114850-164385 / Rev.CMovementsThe Movements button is located in the Setup menu.The Movements function makes it possible to estimate thepos

Pagina 30 - True Motion/Vertical

Parameters115850-164385 / Rev.CNoise LevelThe Noise Level button is located in the Horizontal menu.The Noise level button provides a readout of the cu

Pagina 31

Simrad SH80116850-164385 / Rev.CPaletteThe Palette button is located in the Display menu.The Palette parameter dialogue is used to select backgroundco

Pagina 32

Parameters117850-164385 / Rev.CPanel BacklightThe Panel Backlight button is located in the Display menu.The Panel Backlight controls the illumination

Pagina 33 - SONAR OPERATING PANEL

Simrad SH80118850-164385 / Rev.CPP FilterThe PP Filter can be accessed from the Horizontal andVertical menus.The PP Filter (Ping-to Ping filter) reduc

Pagina 34 - Main switch

Parameters119850-164385 / Rev.CPulse FormThe Pu lse Form is accessed from the Horizontal and Verticalmenus.The Pu lse Form parameter dialogue is used

Pagina 35 - (D) Gear symbol

System description3850-164385 / Rev.CSonar room unitsThe Transceiver Unit is located in the sonar room, close to theHull Unit. One signal cable is use

Pagina 36 - Trawl symbol

Simrad SH80120850-164385 / Rev.CCW (Continuous Wave)The frequency of the transmitter pulse is here constant, equal tothe selected frequency (if the op

Pagina 37

Parameters121850-164385 / Rev.CRangeThe Range parameter can be accessed from the button in theHorizontal and Vertical menus.Horizontal and vertical ra

Pagina 38 - Vertical gain

Simrad SH80122850-164385 / Rev.CRange (Catch View)The Range (Catch View) button is located in the Catch Viewmenu.The CatchView menu is activated by pr

Pagina 39 - Horizontal range

Parameters123850-164385 / Rev.CRCG (Reverberation Controlled Gain)The RCG button is located in the Horizontal and Verticalmenus.The RCG (Reverberation

Pagina 40

Simrad SH80124850-164385 / Rev.CRecallThe Recall button is located in the Store/Recall menu, which isaccessed from the Setup menu.The Recall button is

Pagina 41

Parameters125850-164385 / Rev.CRulerTo create a ruler, open the Object pop-up menu by clickingObject on the Sonar Operating Panel (or the right mouseb

Pagina 42 - Position track

Simrad SH80126850-164385 / Rev.CScaleThe Scale button is located in the Geo View menu.The GeoView menu is activated by pressing the View button onthe

Pagina 43 - Target track

Parameters127850-164385 / Rev.CSchoolThe School button is located in the Setup menu.The School parameter is used to obtain information of the volumees

Pagina 44 - Auto tilt

Simrad SH80128850-164385 / Rev.CScientific Output (Option)The Scientific Output button is located in the Setup menu.The Scientific Output functionalit

Pagina 45

Parameters129850-164385 / Rev.CSearch SectorThe Search Sector is accessed from the Bearing paramaterdialogue, which is turn is opened from the Horizon

Pagina 46 - OPERATION

Simrad SH804850-164385 / Rev.CSystem diagramA simplified SH80 system diagram is shown.(A) = Colour display(B) = Operating Panel(C) = Sonar Processor U

Pagina 47 - Maintaining the sonar

Simrad SH80130850-164385 / Rev.CSearch StepThe Search Step is accessed from the Bearing paramaterdialoge, which is turn is opened from the Horizontal

Pagina 48 - Start and stop procedures

Parameters131850-164385 / Rev.CSlant Range/True RangeThe Slant Range/True Range button is located in theCosmetics menu,whichinturnisaccessedfromtheDis

Pagina 49 - Stop procedure

Simrad SH80132850-164385 / Rev.CSpeedThe Speed parameter is accessed by pressing the Spd (Speed)buttonintheStatus dialogue at the bottom of the menus.

Pagina 50 - Dry-docking safety measures

Parameters133850-164385 / Rev.CStabilizerThe Stabilizer button is located in the Setup menu.When the stabilizer isactive, the transducer beam will bes

Pagina 51 - Menu operation

Simrad SH80134850-164385 / Rev.CStatusThe Status dialogue is the default view displayed in the lower,right hand corner of the screen.The Status dialog

Pagina 52 - Screen presentations

Parameters135850-164385 / Rev.CStoreThe Store button is located in the Store/Recall menu, which isaccessed from the Setup menu.The Store button is use

Pagina 53

Simrad SH80136850-164385 / Rev.CTarget TrackThe Target Track button is located in the GeoView menu.The GeoView menu is activated by pressing the View

Pagina 54 - Menu structure

Parameters137850-164385 / Rev.CTiltThe Tilt parameters are accessed from the Horizontal menu.The Tilt is normally controlled from the Sonar OperatingP

Pagina 55 - Menu buttons

Simrad SH80138850-164385 / Rev.CTime and DateThe Time and Date dialogue box is accessed by pressing theTime or Date buttons in the default Status dial

Pagina 56

Parameters139850-164385 / Rev.CTrack HistoryThe Track History is accessed from the Cosmetics menu.The Track History lines show the movement history of

Pagina 57

System description5850-164385 / Rev.C

Pagina 58 - Stored parameters

Simrad SH80140850-164385 / Rev.CTrack WindowThe Track Window parameter is accessed from the Setupmenu.The Track Window command enables you to adjust t

Pagina 59 - Visual aids

Parameters141850-164385 / Rev.CTransducerThe Transducer button is located in the Status dialogue at thebottom of the menus.The Transducer position is

Pagina 60 - Cosmetics

Simrad SH80142850-164385 / Rev.CTVG (Time Variable Gain)The TVG button is located in the Horizontal and Verticalmenus.The TVG controls the gain in the

Pagina 61 - Select and

Parameters143850-164385 / Rev.CTx PowerThe Tx Power button is accessed from the Horizontal andVertical menus.TheTX Power isusedtoswitchtransmitteroutp

Pagina 62

Simrad SH80144850-164385 / Rev.CUnitsThe Units button is located on the Display menu. Whenactivated, it opens the Engineering Units parameter dialogue

Pagina 63 - Installation of options

Parameters145850-164385 / Rev.CUser SettingUser Setting is accessed from the Setup menu.The User Setting is used to store the parameter settingsfor di

Pagina 64

Simrad SH80146850-164385 / Rev.CWind DirectionThe Wind Direction button is located in the Setup menu.The wind marker is show in the outer area of the

Pagina 65 - On-line help

Parameters147850-164385 / Rev.CWind SpeedThe Wind Speed button is located in the Setup menu.The Wind Speed is not used as a parameter in the sonar. It

Pagina 66 - MENU DESCRIPTIONS

Simrad SH80148850-164385 / Rev.CZoomThe Zoom button is located in the Vertical View menu.The Zoom function is used to zoom in on the vertical view aro

Pagina 67 - Active menus

Parameters149850-164385 / Rev.CZoom ScaleThe Zoom button is located in the Vertical View menu.The Zoom Scale is used for scaling the zoom around the b

Pagina 68 - Horizontal

Simrad SH806850-164385 / Rev.COptionsGeneralThe standard SH80 sonar is a single 116 kHz version with beamstabilization.The beam stabilization was an o

Pagina 69 - Vertical

Simrad SH80150850-164385 / Rev.CON-BOARD MAINTENANCEIntroductionThis section deals with maintenance work that may be carriedout by the user. In additi

Pagina 70

On-board maintenance151850-164385 / Rev.CPreventive maintenance scheduleObserve the following schedule for preventive maintenance onthe SH80 sonar sys

Pagina 71

Simrad SH80152850-164385 / Rev.CWheelhouse unitsCleaningThe units must be kept clean and dry. Remove salt water residuewith a soft cloth moistened in

Pagina 72 -  Inspect Object, page 108

On-board maintenance153850-164385 / Rev.CMC70SonarProcessorUnitThe two dust filters on the MC70 are located on the air inlets onthe front side of the

Pagina 73 - Temporary menus

Simrad SH80154850-164385 / Rev.CTransceiver UnitDust filterThere is a dust filter in the bottom of the Transceiver Unit. Toavoid overheating, this mus

Pagina 74

On-board maintenance155850-164385 / Rev.CIf one of the fuses are blown, the lamp L203 should be lit, whilelamp L204 should be extinguished. If lamp L2

Pagina 75 - Store/Recall

Simrad SH80156850-164385 / Rev.CHull unitGeneralThe sonar hull unit must be under continuous watch as a part ofthe vessel’s machinery. As the hull uni

Pagina 76 - System test

On-board maintenance157850-164385 / Rev.CHull unit familiarizationObserve the illustration below for the identification of the mainparts.A) Upper limi

Pagina 77 - Menu descriptions

Simrad SH80158850-164385 / Rev.CDocking the vesselWhen docking the vessel, great care must be taken not todamage the sonar trunk and protecting bliste

Pagina 78 - Sort Modes

On-board maintenance159850-164385 / Rev.COn vessels which have been in dock, the Hull Unit must bethoroughly examined, and the hoist/lower functions m

Pagina 79 - Pop-up menus

System description7850-164385 / Rev.CFunctional descriptionIntroductionThe basic principles of the SH80 sonar are unique because ofthe 240 transmitter

Pagina 80 - View pop-up

Simrad SH80160850-164385 / Rev.CCleaning the transducerThe transducer normally needs little attention. However, thetransducer face should be inspected

Pagina 81 -  View button, page 30

On-board maintenance161850-164385 / Rev.CHoist motor overload protectionTo prevent the hoist/lower motor from overload, an overloadcircuit breaker S30

Pagina 82 - Object pop-up

Simrad SH80162850-164385 / Rev.CEmergency hoisting and loweringIn case of a failure or an emergency in the normal hoist/loweroperation controlled from

Pagina 83

On-board maintenance163850-164385 / Rev.CLubrication of the Hull UnitFrom the factory, the Hull Unit is lubricated with the types of oilor grease as s

Pagina 86 - VerticalView

E 2005 Simrad ASISBN 82-8066-007-0Simrad ASStrandpromenaden 50Box 111N-3191 HortenTelephone: +47 33 03 40 00Facsimile: +47 33 04 29 87M A X I M I Z I

Pagina 87 - CatchView

Simrad SH808850-164385 / Rev.C60 degrees verticalsliceOmni/VerticalcombinationIn addition to the Omni picture, the vertical slice is especiallyuseful

Pagina 88 - Messages

System description9850-164385 / Rev.CStabilization systemWhen the beam stabilizer is activated, both horizontal andvertical beams will be stabilized e

Pagina 90 - Operator alarms

Simrad SH8010850-164385 / Rev.CHowever, the sound absorption in salt water increases with thefrequency, thus giving the lower frequencies a longer det

Pagina 91 - System alarms

System description11850-164385 / Rev.CWhen the stabilisation system is active, the tilt angle for eachbeam will automatically be corrected relative to

Pagina 92 -  Message Bar, page 111

Simrad SH8012850-164385 / Rev.CPeripheral equipmentThe SH80 sonar requires connection to a speed log and a coursegyro. An inaccurate log or gyro input

Pagina 93 - PARAMETERS

Display modes13850-164385 / Rev.CDISPLAY MODESIntroductionThis chapter describes the SH80 display modes. The variousmodes represent the graphical pres

Pagina 94 - Alphabetical list

Simrad SH8014850-164385 / Rev.CBow UpWhen Bow Up mode is selected, the vessel symbol is stationaryon the screen with the bow pointing upwards. The ech

Pagina 95

Display modes15850-164385 / Rev.CNorth UpWhen the North Up mode is selected, true north is always upon the screen. The vessel symbol is stationary wit

Pagina 96

Simrad SH8016850-164385 / Rev.CTrue MotionWhen the True Motion mode is selected, the picture is lockedto a geographical position, where the vessel mov

Pagina 97

Display modes17850-164385 / Rev.C180°/AudioWhen the 180°/Audio mode is selected, the upper half of thescreen shows a 180 degrees bow-up presentation,

Pagina 98 - Bearing (Horizontal)

Simrad SH8018850-164385 / Rev.C270°/VerticalThe 270°/Vertical mode is specially designed for purse seining.The vertical half slice is displayed in the

Pagina 99

Display modes19850-164385 / Rev.CBow Up / VerticalWhen the Bow Up / Vertical mode is selected, the picture isdivided into three sections; where the le

Pagina 100 - Bearing (Display)

850-164385 / Rev.CSH80High frequency fishery sonarOperator manualWARNINGThe sonar must never be powered up when the ship isin dry dock. The transducer

Pagina 101 - Bearing (Vertical)

Simrad SH8020850-164385 / Rev.CTrue Motion/VerticalWhen the True Motion/Vertical mode is selected, the picture isdivided into three sections; where th

Pagina 102 - Colour Threshold

Display modes21850-164385 / Rev.CDual 1The Dual 1 mode is a kind of “two sonars in one” operation,where each presentation is updated for every secondt

Pagina 103 -  Colour Threshold, page 92

Simrad SH8022850-164385 / Rev.CDual 2The Dual 2 mode is very similar to the Dual 1 mode previouslydescribed, but the “two sonars” are presented next t

Pagina 104 - Data Source

Sonar Operating Panel23850-164385 / Rev.CSONAR OPERATING PANELIntroductionYou may enter operational commands directly on the SonarOperating Panel. Son

Pagina 105 - Dead Reckoning

Simrad SH8024850-164385 / Rev.CMain switchMain switch functions control power to the sonar, hoisting andlowering of the transducer and indicates the t

Pagina 106 - Default Setting

Sonar Operating Panel25850-164385 / Rev.CSymbolThe Symbol functions provide on-screen graphic references fortargets, own ship and fishing gear.(A) Tar

Pagina 107 - Direction Indicator

Simrad SH8026850-164385 / Rev.CSeine circleThis is a useful aid in planning the shooting of the purse seine. Itis used as follows:1. Press the Gear bu

Pagina 108 - Edit Gear (Purse)

Sonar Operating Panel27850-164385 / Rev.CModeThe four Mode buttons can be used to select either the fourfavourite display modes or user settings. The

Pagina 109 - Edit Gear (Trawl)

Simrad SH8028850-164385 / Rev.CGainGain controls are specified as either horizontal or vertical.Horizontal gainThe two upper buttons control receiver

Pagina 110 -  Gear, page 106

Sonar Operating Panel29850-164385 / Rev.CRangeRange controls are specified as either horizontal or vertical.Horizontal rangeThe two upper buttons cont

Pagina 111 - Edit School

About this documentRev Date Written by Checked by Approved byRev.C11.02.05 RBr SØJ OBGUpdated for software version 1.2.X© 2005 Simrad ASISBN 82-8066-0

Pagina 112 - External Synchronization

Simrad SH8030850-164385 / Rev.CCursorThe cursor is used for on-screen cursor orientation and menuoperation.MenuThe Menu buttonisusedforselection betwe

Pagina 113 - Fish Alarm

Sonar Operating Panel31850-164385 / Rev.CTrackballThe trackball controls the cursor. The cursor changesappearance in relation to its location on the s

Pagina 114 - Frequency

Simrad SH8032850-164385 / Rev.CTrainThe audio channel is displayed as a continuous white line. It canbe trained either manually or automatically. The

Pagina 115

Sonar Operating Panel33850-164385 / Rev.CWhen the Auto Tilt function is activated in the Position Trackmode the tilt search centre is automatically ad

Pagina 116 -  Edit gear (Trawl ), page 99

Simrad SH8034850-164385 / Rev.CTiltManual tiltIn Manual mode the transducer may be tilted within thesystems limits by pressing the Tilt up (arrow) or

Pagina 117

Sonar Operating Panel35850-164385 / Rev.CVariousThe buttons grouped under various are Zoom, Record, Muteand Off Centre.MuteThe Mute button is not used

Pagina 118 - Inspect Object

Simrad SH8036850-164385 / Rev.COPERATIONIntroductionAll operation of the sonar is normally made from the SonarOperating Panel. Optionally, a standard

Pagina 119 - Language

Operation37850-164385 / Rev.CMaintaining the sonarMaintenance proceduresTo ensure the best possible reliability of the SH80 sonar, it isimportant to f

Pagina 120

Simrad SH8038850-164385 / Rev.CStart and stop proceduresNote: Before you start the sonar, check that the water depth issufficient, and that the vessel

Pagina 121 - Message Bar

Operation39850-164385 / Rev.CDisconnected mainsIn case of power failure, or if the mains plug on the SonarProcessor Unit has been disconnected, the so

Pagina 122 -  Sort Modes menu, page 68

Operator manualI850-164385 / Rev.CSections1. System descriptionThis chapter provides a brief introduction to the SH80, and defines the mainunits. Refe

Pagina 123 - Mode Buttons

Simrad SH8040850-164385 / Rev.CProcedures for emergency hoisting are provided in theMaintenance chapter.Dry-docking safety measuresTo prevent inadvert

Pagina 124 - Movements

Operation41850-164385 / Rev.CMenu operationIntroductionThe menu system on the SH80 sonar is designed to allow foreasy and fast access to the parameter

Pagina 125 - Noise Level

Simrad SH8042850-164385 / Rev.CScreen presentationsThe menu can be set up for permanent display, or available onlywhen required for parameter alterati

Pagina 126 - Simrad SH80

Operation43850-164385 / Rev.CFull screenpresentation withthe menu hiddenfrom view(CD15008B)Full screenpresentation withtemporary menu(CD15008C)

Pagina 127 - Panel Backlight

Simrad SH8044850-164385 / Rev.CMenu structureThe menu field on the sonar display contains several differentbuttons, tabs and parameter dialogues.(A) S

Pagina 128 - PP Filter

Operation45850-164385 / Rev.CMenu buttonsEach menu contains several buttons. Each button shows boththe function and the current parameter. The majorit

Pagina 129 - Pulse Form

Simrad SH8046850-164385 / Rev.CSelecting a new parameter valueThe menu system is operated by the trackball and the Selectbutton on the Sonar Operating

Pagina 130 - FM (Frequency Modulation)

Operation47850-164385 / Rev.CThe parameter value shown in the button is operational evenwithout closing the parameter dialogue. This makes it easy tot

Pagina 131

Simrad SH8048850-164385 / Rev.CStored parametersDefault settingsThe parameter settings identified with an asterisk (*), indicatesthe normal setting kn

Pagina 132 - Range (Catch View)

Operation49850-164385 / Rev.CVisual aidsCommon information on the displayIn nearly all display modes, the following information isprovided. The Tilt

Pagina 133

Simrad SH80II850-164385 / Rev.CSYSTEM DESCRIPTION 1...Introduction 1...

Pagina 134 - Recall Mode

Simrad SH8050850-164385 / Rev.CCosmeticsThe choices in the Cosmetics menu allows you to enable ordisable a range of visual aids in the sonar picture.S

Pagina 135 -  Object pop-up menu, page 72

Operation51850-164385 / Rev.CSonar display withVariable RangeMarker (D), CompassCard (E) and VerticalRing (F) enabled.The Vertical Ringreflects the ve

Pagina 136

Simrad SH8052850-164385 / Rev.CSonar display withVertical Depthdividers (G), Trackhistory with MinuteMarkers (H) andBow Marker (I)enabled.(CD15014C)NS

Pagina 137 -  Edit School; page 101

Operation53850-164385 / Rev.CInstallation of optionsThe following options can be installed on the SH80 sonar: Triple- or multiple-frequency Scientif

Pagina 138 - Scientific Output (Option)

Simrad SH8054850-164385 / Rev.CNote: If any time or date adjustments are made during the test period,the option will be closed.Add License String - Th

Pagina 139 - Search Sector

Operation55850-164385 / Rev.COn-line helpThe SH80 sonar is equipped with a comprehensive on-line helpsystem. It is available from all the parameter di

Pagina 140 - Search Step

Simrad SH8056850-164385 / Rev.CMENU DESCRIPTIONSIntroductionThis section provides a detailed description of the completemenu system for the SH80 sonar

Pagina 141 - Slant Range/True Range

Menu descriptions57850-164385 / Rev.CActive menusOverviewThe Active menus are those relevant for the differentoperational modes. The menus are shown w

Pagina 142

Simrad SH8058850-164385 / Rev.CHorizontalThe Horizontal menu is used to control the horizontalpresentations. The parameters chosen are present in all

Pagina 143 - Stabilizer

Menu descriptions59850-164385 / Rev.CVerticalThe Vertical menu is only shown in modes with a vertical slicefunction. All relevant settings, except the

Pagina 144

Operator manualIII850-164385 / Rev.CTilt 34...Various 35...

Pagina 145 - Store Mode

Simrad SH8060850-164385 / Rev.CDisplayThe Display menu is shown in all display modes, and providesaccess to parameters controlling the visual presenta

Pagina 146 - Target Track

Menu descriptions61850-164385 / Rev.CSetupThe Setup menu is shown in all display modes, and gives accessto parameters controlling the processing and a

Pagina 147

Simrad SH8062850-164385 / Rev.CObjectsThe Objects menu is shown in all display modes, and displays therange (R), bearing (B) and depth (D) to all sele

Pagina 148 - Time and Date

Menu descriptions63850-164385 / Rev.CTemporary menusThe Temporary menus are those selected from the activemenus. They are also shown with vertical tab

Pagina 149 - Track History

Simrad SH8064850-164385 / Rev.CCosmeticsThe Cosmetics menu is activated by pressing the CosmeticsbuttonintheDisplay menu. It provides access to variou

Pagina 150 - Track Window

Menu descriptions65850-164385 / Rev.CStore/RecallThe Store/Recall menu is activated by the Store/Recall buttonin the Setup menu.The Store/Recall menu

Pagina 151 - Transducer

Simrad SH8066850-164385 / Rev.CSystem testThe System test menu is activated by the Test buttonintheSetup menu.The System test menu provides several te

Pagina 152 - TVG (Time Variable Gain)

Menu descriptions67850-164385 / Rev.CAbout - This button provides access to a small informationdialogue providing the current software version.The Clo

Pagina 153 - Tx Power

Simrad SH8068850-164385 / Rev.CSort ModesThe Sort Modes menu is activated by the Sort Modes button inthe Setup menu.The Sort Modes menu is used to sel

Pagina 154

Menu descriptions69850-164385 / Rev.CPop-up menusThe pop-up menus are accessed using the View and Objectbuttons on the Sonar Operating Panel, or the m

Pagina 155 - User Setting

Simrad SH80IV850-164385 / Rev.CPop-up menus 69...View pop-up 70...

Pagina 156 - Wind Direction

Simrad SH8070850-164385 / Rev.CView pop-upThe View pop-up menu is accessed using the View button overthe trackball on the Sonar Operating Panel or the

Pagina 157 - Wind Speed

Menu descriptions71850-164385 / Rev.CGrey scale data - This command changes the display from acolour presentation to a black-and-white. The number of

Pagina 158

Simrad SH8072850-164385 / Rev.CObject pop-upThe Object pop-up menu is accessed using the Object buttonover the trackball on the Sonar Operating Panel,

Pagina 159 - Zoom Scale

Menu descriptions73850-164385 / Rev.CParametersBasic f unctions - These choices provide the same functions astheir respective buttons on the Sonar Ope

Pagina 160 - ON-BOARD MAINTENANCE

Simrad SH8074850-164385 / Rev.CView menusThe View menus are activated from the View pop-up menu,which again is accessed using the View button on the S

Pagina 161

Menu descriptions75850-164385 / Rev.CGeoViewThe GeoView menu is activated by pressing the View button onthe Sonar Operating Panel or the middle mouse

Pagina 162 - Wheelhouse units

Simrad SH8076850-164385 / Rev.CVerticalViewThe VerticalView menu is activated by pressing the Viewbutton on the Sonar Operating Panel or the middle mo

Pagina 163 - MC70SonarProcessorUnit

Menu descriptions77850-164385 / Rev.CCatchViewThe CatchView menu is activated by pressing the View buttonon the Sonar Operating Panel or the middle mo

Pagina 164 - Transceiver Unit

Simrad SH8078850-164385 / Rev.CMessagesMessage categoriesWhen necessary, the sonar will provide you (or your serviceengineer) with operational and tec

Pagina 165

Menu descriptions79850-164385 / Rev.CWarningsThe Warnings menu is activated from the Warnings button inthe Message bar.The Warnings menu displays the

Pagina 166 - Hull unit

Operator manualV850-164385 / Rev.CMessage Bar 111...Mode 112...

Pagina 167 - Hull unit familiarization

Simrad SH8080850-164385 / Rev.COperator alarmsThe Operator alarms dialogue is activated from theOp.Alarms buttonintheMessage bar.The Operator alarms m

Pagina 168 - Docking the vessel

Menu descriptions81850-164385 / Rev.CSystem alarmsThe System alarms dialogue is activated from the Sys.AlarmsbuttonintheMessage bar.The System alarms

Pagina 169

Simrad SH8082850-164385 / Rev.CErrorsThe Errors dialogue is activated from the Errors buttonintheMessage bar.The Errors menu displays the alarms issue

Pagina 170 - Cleaning the transducer

Parameters83850-164385 / Rev.CPARAMETERSAbout parameter dialogues and helpThis chapter describes all the parameter dialogues accessed fromthe menu sys

Pagina 171

Simrad SH8084850-164385 / Rev.CAlphabetical listThe following is an overview of available parameters incorporated in the SH80 sonarsystem. About, pag

Pagina 172

Parameters85850-164385 / Rev.CAboutThe About parameter dialogue is accessed from the System testmenu.The About dialogue is only used to provide inform

Pagina 173 - Lubrication of the Hull Unit

Simrad SH8086850-164385 / Rev.CBeamThe Beam parameters are accessed from the Horizontal menu.The Beam command enables you to select the vertical beam

Pagina 174

Parameters87850-164385 / Rev.CThe following buttons can be used.Wide - This button is used to select the upper range for the widebeam width in Auto mo

Pagina 175

Simrad SH8088850-164385 / Rev.CBearing (Horizontal)The Bearing parameters are accessed from the Horizontalmenu.The Bearing of the audio channel is nor

Pagina 176 - ISBN 82-8066-007-0

Parameters89850-164385 / Rev.CAbsolute/RelativeClick Absolute to set bearing of the audio channel to be relativeto true north. Click Relative to set t

Commenti su questo manuale