Simrad SH80High frequency fishery sonarInstallation manualA L W A Y S A T T H E F O R E F R O N T O F T E C H N O L O G Ywww.simrad.com
Simrad SH80VI851-164300 / C9.2 Check--list before start--up commences 86...9.3 Starting up the stand--by power supply 87...
Simrad SH8084851--164300 / C8.10 Trackball / mouse connectionIn addition to the standard operating panel, an extra trackball ormouse with USB interfac
Start--up procedures85851--164300 / C9 START-UP PROCEDURES9.1 IntroductionThe procedures in this chapter shall be carried out once all thehardware uni
Simrad SH8086851--164300 / C9.2 Check-list before start-up commencesBefore you commence with the start-up procedure, check thefollowing items. To ensu
Start--up procedures87851--164300 / C9.3 Starting up the stand-by power supplyIn order to start up the sonar units, the +24 Vdc stand-by powersupply i
Simrad SH8088851--164300 / C- Write down the measured voltage here:Supply voltage (Vac):5 Check that the measured voltage corresponds to the voltage(1
Start--up procedures89851--164300 / C9.4 Starting up the Hull UnitIntroductionObserve the following procedure to start up the Hull Unit. Toensure corr
Simrad SH8090851--164300 / CS 302K301 K302HAND CRANKS 303(CD3125 / WMF / GIF)S301S302K302S303HandcrankREMOTEHOIST STOPLOWERK301Figure 31 TheMo
Start--up procedures91851--164300 / C(CD6294B)Hoist motorHand crankBrake releaseUpper limitswitch S304Lower limitswitch S305Motor ControlUnitFigure 32
Simrad SH8092851--164300 / CApply 3-phase AC powerYou will now apply 3-phase mains power to the hull unit.1 Reinsert the 3-phase mains fuses for the h
Start--up procedures93851--164300 / CFigure 33 Mainsconnection to themotor230 Vac380 / 440 Vac3 Set the hoisting/lowering switch S302 to Lower.4 Check
Installation manualVII851-164300 / C10.3 Speed log 124...Introduction 124...
Simrad SH8094851--164300 / C11 Set the hoisting/lowering switch to the Hoist position t ocompletely hoist the transducer.- Hoisting will be stopped au
Start--up procedures95851--164300 / C9.5 Starting up the Wheelhouse UnitsIntroductionIf the AC mains plug on the SH80 Sonar Processor Unit has beendis
Simrad SH8096851--164300 / CDisplay set-upObserve the following procedure to set up the display and retrievesimulated sonar echoes.1 Refer to the inst
Start-up procedures97851-164300 / C9.6 Checking the Operating PanelIntroductionThe simulated echoes makes it possible to test out most of theoperation
Simrad SH8098851-164300 / CSYMBOL(CD5347)Target markerOwn ship markerCircle markerGear symbolFigure 36 The Symbolfield with the threemarkers and the G
Start-up procedures99851-164300 / Cb Press the Horizontal tab to bring up this menu.c Press the Gain H- and Gain H+ buttons repeatedly (field4 on the
Simrad SH80100851-164300 / CObject menu13 Check the Object menu.a Move the cursor to a new position inside t he echo area.b Press the Object button (f
Start-up procedures101851-164300 / Cb Check that the white audio line on the screen trainscorrespondingly.c Try both directions.18 Check the Position
Simrad SH80102851--164300 / C9.7 Checking the hoisting/lower systemIntroductionThe following set of procedures requires two persons. One personmust be
Start-up procedures103851-164300 / CChecking the bridge functionsNote This procedure must be performed simultanously with the nextprocedure; Checking
Simrad SH80VIII851-164300 / CEthernet with RJ45 166...Standard VGA cable 167...
Simrad SH80104851-164300 / Cc When lower position has been reached, check that theLED next to the Down button illuminates continuously,that the audibl
Start-up procedures105851-164300 / Cc When upper position has been reached, check that theLED next to the Up button illuminates continuously, thatthe
Simrad SH80106851-164300 / CBlank pageThis page is intentionally left blank. It allows you to remove the next test procedure fromthe manual, and bring
Start-up procedures107851-164300 / CChecking the sonar room functionsNote This procedure must be performed simultanously with theprocedure and checkli
Simrad SH80108851--164300 / C9.8 StartinguptheTransceiverUnitObserve this test procedure to power up the Transceiver Unit forthe f irst time.F2068AF20
Start--up procedures109851--164300 / C7 Check that the Transceiver Unit starts up after approximatelyone minute, and that the two LEDs marked D5 and D
Simrad SH80110851-164300 / C9.9 Self-noise testThis test procedure will allow you to check the system’s self-noise.Observe the following procedure to
Start--up procedures111851--164300 / C9.10 System start-upIntroductionTo do the final tests, the vessel must be in the sea. This is becausethe transdu
Simrad SH80112851--164300 / CStarting up the transmitterThe following set of procedures requires two persons. One personmust be stationed on the bridg
Start-up procedures113851-164300 / CActions on the bridgeNote This procedure must be performed simultanously with the nextprocedure; Actions in the so
Installation manualIX851--164300 / CDocument revisionsRev Date Written by Checked by Approved byA 22.01.02 RBr SØJ SØJB 11.03.02 RBr SØJ SØJC 26.08.03
Simrad SH80114851-164300 / CBlank pageThis page is intentionally left blank. It allows you to remove the next test procedure fromthe manual, and bring
Start--up procedures115851--164300 / CActions in the sonar roomNote This procedure must be performed simultanously with the previousprocedure; Actions
Simrad SH80116851--164300 / C9.11 Alignment of the sonar pictureIndependent of the hull unit orientation, the alignment is alwaysdefined as:• the angl
Start--up procedures117851--164300 / Cg Press the Alignment button.h Enter the estimated alignment angle.3 Check that the echo picture on the display
Simrad SH80118851-164300 / C9.12 Setting own ship parametersShip dimensionsTo get the correct size of the vessel symbol on the display, thelength and
Start-up procedures119851-164300 / CFigure 40 Origodefinition-Y+Y+X-XOrigo(CD6748)4 Press the X Position button and enter the correct value.5 Press th
Simrad SH80120851--164300 / C10 TESTING THE PERIPHERAL EQUIPMENT10.1 IntroductionThe physical connections of the peripehral sensors has beenpreviously
Testing the peripheral equipment121851--164300 / C10.2 GeneralDefault interface settingsThe sensor settings are all preset to these recommendedconnect
Simrad SH80122851--164300 / C13 Press Close to finish.If you enter a wrong value and the sensor interface does not work,you can change the parameters
Testing the peripheral equipment123851--164300 / CFigure 42 The Object Inspector7 Select SensorIOControl on the list by pressing on the + signin front
Simrad SH80X851-164300 / CBlank page
Simrad SH80124851--164300 / C10.3 Speed logIntroductionThe speed log can come from three different sensor types. Tick offfor the type which will be co
Testing the peripheral equipment125851--164300 / C1 Access the I/O Setup menu.2 Select Sensors in the I/O Setup menu, then Speed andfinally Speed Log.
Simrad SH80126851--164300 / C10.4 Course gyroIntroductionThe heading can come from two different sensor types. Tick off forthe type which will be conn
Testing the peripheral equipment127851--164300 / C3 Observe the Sensor Config submenu appears at the bottomof the menu field.4 Change the settings in
Simrad SH80128851--164300 / C10.5 (D)GPSObserve the following procedure to test the GPS input:1 Access the I/O Setup menu.→ A procedure for this is lo
Testing the peripheral equipment129851--164300 / C10.6 Echo sounderThe SH80 Processor Unit can read the depth information from anecho sounder on stand
Simrad SH80130851--164300 / C10.7 Trawl systemObserve the following procedure to test the trawl system interface.1 Access the I/O Setup menu.→ A proce
Testing the peripheral equipment131851--164300 / C10.8 Purse seine systemObserve the following procedure to test the purse seine interface.1 Access th
Simrad SH80132851--164300 / C10.9 Radio buoy systemObserve the following procedure to test the radio buoy systeminterface.1 Access the I/O Setup menu.
Testing the peripheral equipment133851--164300 / C10.10 Current meter systemObserve t he following procedure to test the Current Meter systeminterface
Installation manualXI851--164300 / CHigh voltage safety warningPrecautionary measuresThe voltages used to power this equipmentare potentially lethal.
Simrad SH80134851--164300 / C11 TECHNICAL SPECIFICATIONS11.1 Power specificationsSonarProcessorUnitMC70• Voltage:- Nominal: 115 / 230 Vac, single phas
Technical specifications135851--164300 / CSonarProcessorUnitMC70• Weight: Approximately 15 kg• Dimensions (WDH): 452 x 410 x 267 mm→ Refer to the outl
Simrad SH80136851--164300 / C• Storage temperature: -40to+70°C• Humidity: 5 to 95% relative non-condensingSonar Interface Unit• Operational temperatur
Technical specifications137851--164300 / C11.4 Telegram formatsIntroductionThe SH80 can send and receive information from several differentperipherals
Simrad SH80138851--164300 / CNMEA 0183The NMEA 0183 Standard is the most common protocol used forreceiving and transmitting sensor data. The following
Technical specifications139851--164300 / CGyroThe sonar can receive the following gyro telegrams.• Heading, magnetic• Heading, trueHeading, magnetic$?
Simrad SH80140851--164300 / CSpeed logThe SH80 can interface to an external speed log via Ethernet, or aserial line using the NMEA 0183 standard for r
Technical specifications141851--164300 / CTimeThe SH80 software provides an interface to an external timesynchronisation unit. The communication can t
Simrad SH80142851--164300 / CTrawl systemsThe SH80 interfaces a trawl system via Ethernet or on a serial line.The serial interface uses either the NME
Technical specifications143851--164300 / CTrawl position in cartesian co-ordinates@IITPC,x,M,y,M,z,M<cr><lf>where (from left towards right
Simrad SH80XII851--164300 / CArtificial respiration1 Kneel besides the victim’s head. Place onehand under his neck and lift, allowing hishead to fall
Simrad SH80144851--164300 / CTrawl headrope to footrope and bottom@IIHFB,x.x,M,y.y,M<cr><lf>where (from left towards right):Component Cont
Technical specifications145851--164300 / CTrawl to shoal distance@IITTS,x,M,y,P,z,M<cr><lf>where (from left towards right):Component Conte
Simrad SH80146851--164300 / CITI OutputsThe SH80 transmits the following NMEA telegrams to the ITIsystem.• Tracked target position or markerTracked ta
Technical specifications147851--164300 / CFS3300 Trawl systemThe serial output of the FS3300 system sends a 2-byte binary depthvalue. With a measureme
Simrad SH80148851--164300 / CGlobal Positioning System (GPS)The SH80 can interface an external Global Positioning System(GPS) via Ethernet or by a ser
Technical specifications149851--164300 / CGlobal positioning system fix data$??GGAhhmmss.ss,ddmmhh,,N,dddmm.hh,W,hhmmss.ss,a,x,xx,x.x,x.x,M,x.x,M,x.x,
Simrad SH80150851--164300 / CEcho sounderThe SH80 i nterfaces an external echo sounder via Ethernet or aserial line for reception of depth information
Technical specifications151851--164300 / CSounder depth below surface (Special)This telegram has been developed by Simrad.$SDDBS,,,y.y,M,,,tttttt<c
Simrad SH80152851--164300 / CSea current sensorThe SH80 interfaces to an external sensor for reception of seacurrent data. The interface is made via E
Technical specifications153851--164300 / CWind sensorThe SH80 interfaces an external wind sensor via Ethernet or aserial line using the NMEA 0183 stan
Introduction1851--164300 / C1INTRODUCTION1.1 Purpose and descriptionIntroductionThe purpose of this manual is to provide the information and basicdraw
Simrad SH80154851--164300 / CWind speed and angle (relative)$??VWR,x.x,a,x.x,a,A<cr><lf>where (from left towards right):Component Content?
Drawing file155851--164300 / C12 DRAWING FILE12.1 OverviewThis chapter contains cable details and i nstallation drawings.Cable details→ C1 - W301 AC p
Simrad SH80156851--164300 / CMounting trunk, outline dimensions→ SH80 Mounting trunk (830-113234), page 176.Optional trunk, outline dimensionsNoneBlin
Drawing file157851--164300 / CInternal control and communicationcablesThese drawings detail the three cables used between the SH80Sonar Processor Unit
Simrad SH80158851--164300 / CC6 - Ethernet communicationThis is a standard CAT5 cable terminated with RJ45 connectors ineach end. Cable length is appr
Drawing file159851--164300 / CSonar Interface UnitSerial linesThe Sonar Interface Unit provides seven serial linecommunication ports. These are availa
Simrad SH80160851--164300 / CPulse speed logThis interface has been provided for a pulse speed log.W208C / Rev.APulse log621811471039125Sonar Interfac
Drawing file161851--164300 / CC15 - Transceiver Unit interfaceThis is the main interconnection cable between the Sonar InterfaceUnit and the Transceiv
Simrad SH80162851--164300 / CSynchronizationThis cable allows external synchronization of the sonar’stransmission.W208F / Rev.ASynchronization62181147
Drawing file163851--164300 / CTransceiver Unit to Motor Control UnitThis is the main intercommection cable between the SH80Transceiver Unit and the Mo
Simrad SH802851--164300 / C1.2 System diagramA simplified SH80 system diagram is shown.Legend:(A) = Colour display(B) = Operating Panel(C)=SonarProces
Simrad SH80164851--164300 / CStandard AC power cableThis cable is a standard three-wire power cable. It is commerciallyavailable in standard lengths,
Drawing file165851--164300 / CPower to Hull UnitThis cable is used to connect AC power to the Motor Control Unit,and thus also to the hull unit’s hois
Simrad SH80166851--164300 / CEthernet with RJ45This cable contains the Ethernet connection. RJ45 plugs are usedto terminate the cable. Note that these
Drawing file167851--164300 / CStandard VGA cableThis is a standard display cable used to connect the video signals.The cable is normally physically fa
Simrad SH80168851--164300 / CStandard USB cableThis is a standard commercial USB cable terminated with A andB plugs in either ends. The cable can be u
Drawing file169851--164300 / COperator panelThis cable is used to connect the Operator Panel to the SonarProcessor Unit and Sonar Interface Unit. The
Simrad SH80170851--164300 / C12.3 Installation drawingsThe SH80 installation drawings are provided on the next pages.
Drawing file171851--164300 / C834-204688Rev.APage 1 of 1(CD5862)Sonar Operating PanelOutline dimensions150370321016All measurements in mm.The drawing
Simrad SH80172851--164300 / C410375202441452267N/ARev.APage 1 of 1(CD7006A)MC70 Sonar Processing UnitOutline dimensionsNote:All measurements are in mm
Drawing file173851--164300 / C149313Ø7 mm253280(CD7026B)N/ARev.APage 1 of 1(CD7026B)Sonar Interface UnitOutline dimensionsNote:All measurements are in
Introduction3851--164300 / C(CD6480B)GFACDBEWheelhouseSonar room115/230 Vac115/230 Vac115/230 Vac230/380/440 Vac3-phaseFigure 1 SH80 system diagram
Simrad SH80174851--164300 / C520470750545Door not hinged857542071AiroutletAir inletTransducercable plug(fastened witheight bolts)Extender through insu
Drawing file175851--164300 / C372245ø27313909201000ø37014 5/8"9 3/8"10 3/4"54 3/4"36 1/4"39 3/8"14 9/16"TBDRev.APag
Simrad SH80176851--164300 / C27312.50ø330180.312 Holes,spacing30 degrees55ø37092020830-113234Rev.BPage 1 of 1(CD6381)Mounting trunkAll measurements in
Drawing file177851--164300 / C599-051344Rev.1Page 1 of 1(CD6395)Blind panel for trunk30o30o30o12 holes, ø18 mmAfter-treatment:Sand-blast, thenpaint wi
Simrad SH80178851--164300 / C13 INSTALLATION REMARKSUse these pages to document comments and remarks concerningthe installation. When the installation
Installation remarks179851--164300 / C---------------------------------------------------------(Party / Date / Signature)-----------------------------
E 2003 Simrad ASISBN 82 -8066-005-4WO R L D W I D E M A N U F A C T U R E R O F M A R I N E E L E C T R O N I C SManufacturer:Simrad ASStrandp
Simrad SH80Installation manualSimrad SH80Installation manualSimrad SH80Installation manualSimrad SH80Installation manual
Simrad SH804851--164300 / C1.3 Scope of supplyMain unitsThe standard Simrad SH80 sonar system is comprised of thefollowing main units:Unit Order numbe
Introduction5851--164300 / CInstallation trunkThe installation trunk may be fabricated by the shipyard orsupplied by Simrad:Unit Order numberSH80 Inst
Simrad SH806851--164300 / CInterface for scientific applicationsThis Ethernet interface include outputs of sonar beam data, sonarsettings and processe
Introduction7851--164300 / C1.4 Peripheral equipmentRequired inputsThe Simrad SH80 sonar system requires input from both a speedlog and a course gyro.
Simrad SH808851--164300 / CNote that in addition to navigational data, the (D)GPS may also beused for the input of speed log information. Most (D)GPS
Introduction9851--164300 / C1.5 Supply conditionsPurposeThe following supply conditions are applicable to standard SimradSH80 deliveries and associate
Simrad SH8010851--164300 / C1.6 General safety rulesThe system operates on 115 and/or 230 / 380 / 440 Vac, 50/60 Hz.WARNING This voltage can be lethal
Introduction11851--164300 / C1.7 Installation requirementsResponsibility and approvalThe Simrad SH80’s Hull Unit sleeve has been approved by DetNorske
Simrad SH8012851--164300 / CDry dockingMake sure that ample clearance under the sonar trunk and/orprotection blister is provided when dry docking the
Introduction13851--164300 / C1.8 Equipment handlingIntroductionThis chapter describes how to transport, pack and unpack, clean,preserve and store elec
Simrad SH80High frequency fishery sonarWARNINGThe sonar must never be powered up when the ship isin dry dock. The transducer will be damaged if ittran
Simrad SH8014851--164300 / CHeavy units may be equipped with lifting lugs for transportationby crane within the workshop or installation area. Before
Introduction15851--164300 / C- “Special circumstances” may be suspected damage to thecrate and its content, or inspections by civil authorities.- If a
Simrad SH8016851--164300 / CInspection and unpackingInspectionAn inspection must be carried out immediately after the unit(s)have arrived at their des
Introduction17851--164300 / C• If the carton has been closed using staples, remove the staplesfrom the carton as you open it. This will reduce the pos
Simrad SH8018851--164300 / CThe transducer face must be protected by a rigid, padded cover(e.g. a wooden box lined with foam rubber) all the time it i
Introduction19851--164300 / CCleaning cabinetsIf the unit may have been exposed to salt atmosphere while it wasin use, it must be thoroughly cleaned b
Simrad SH8020851--164300 / C• All surfaces must be inspected for signs of corrosion, eg.flaking/bubbling paint, stains etc. Damaged or suspect areasmu
Introduction21851--164300 / C• Large units must be placed in a suitable cardboard box orwooden crate. The unit must be protected against physicaldamag
Simrad SH8022851--164300 / CCaution If, for any reason, it is necessary to move the circuit board orcomponents from the conductive service mat, they m
Installation planning23851--164300 / C2 INSTALLATION PLANNINGNote For installation in a previously installed trunk system, first readthe information a
NoteSimrad AS makes every effort to ensure that the information contained within thisdocument is correct. However, our equipment is continuously being
Simrad SH8024851--164300 / C2.2 Location of the Hull UnitFore and aftThe Hull Unit should preferably be located within 1/10 to 1/3 thevessel’s Length
Installation planning25851--164300 / C• Overboard discharges• Dents in the hullAll appendages to the hull, indentations and pipe in/outlets arepotenti
Simrad SH8026851--164300 / C2.3 Sonar room requirementsSizeThe sonar room must be dimensioned to house both the Hull andthe Transceiver Unit. This is
Installation planning27851--164300 / CIn the sonar room, the air inlet should be located in close to the deckand t he outlet as high as possible. A fu
Simrad SH8028851--164300 / CFigure 3 SH80 sonar room arrangement - exampleLightingHatchMinimum loadcapacity: 2 tonnesBulkheadstepsTransceiver UnitMoto
Installation planning29851--164300 / CFigure 4 SH80 sonar room arrangement - exampleTransceiver UnitTransducer cable(Total length 3.5 m)400 (*)Min.550
Simrad SH8030851--164300 / C3SONARTRUNK3.1 Mounting of the trunkThe location of the sonar trunk must be carefully selected.→ Refer to the Installation
Installation trunk31851--164300 / C3.2 ProtectionProtecting blisterA steel blister must be fitted for protection. The blister shown iswelded to the sh
Simrad SH8032851--164300 / C3.4 PrinciplesThe drawings on the next pages illustrate the installation of thesonar trunk.
Installation trunk33851--164300 / CFigure 6 SH80 Trunk installation with extension and oil-filled blister.Fore and aft viewA:B:C: As short as possible
Installation manualI851--164300 / CSectionsThis document is the Installation manual for the Simrad SH80 sonar system. It providesthe information and t
Simrad SH8034851--164300 / CFigure 7 Installation of t he SH80 trunk with open protectionblister. No trunk extension.Fore and aft view15° 15°Bottom vi
Hull unit35851--164300 / C4HULLUNIT4.1 IntroductionThe hull unit is a crucial part of t he sonar system. Due to itsphysical size and weight, and the f
Simrad SH8036851--164300 / C4.2 UnpackingWARNING Do not remove the transducer protection fromthe transducer until just before the Hull Unit isto be lo
Hull unit37851--164300 / CFigure 9 SH80 Hull Unit -Parts identification(CD6294A)Hoist motorMotor ControlUnitTransducercableUpper limitswitch S304Lower
Simrad SH8038851--164300 / C4.3 MountingThe Hull Unit should normally be oriented with thehoisting/lowering motor pointing aft.Figure 10Recommendedori
Hull unit39851--164300 / C4.4 Mechanical supportTo ensure the safety of the sonar system and the vessel, it is veryimportant that the mechanical suppo
Simrad SH8040851--164300 / C4.5 Transducer alignmentNote that the transducer should not be mechanically aligned eventhough the Hull Unit i s oriented
Hull unit41851--164300 / C4.6 Installation check-listRefer to section Sonar room requirements when you fill in thefollowing check list.INSTALLATION CH
Simrad SH8042851--164300 / C5 TRANSCEIVER UNITIntroductionNote The Transceiver Unit must be mounted as a complete unit, i.e. thedoor should not be ope
Transceiver unit43851--164300 / CFigure 11 Mounting the brackets for theTransceiver Unit - side viewAngle bars with threadedholes for shock absorbers.
Simrad SH80II851--164300 / CRemarksReferencesFurther information about the SH80 system may be found in the following manuals:• SH80 Operator manualThe
Simrad SH8044851--164300 / CFigure 12 Mounting the brackets for theTransceiver Unit - forward view(CD1988A)App. 40150Min.150Min.Recommended 1100-1200M
Transceiver unit45851--164300 / CFigure 13 Mounting the Transceiver Unit(CD3110A)
Simrad SH8046851--164300 / C6 WHEELHOUSE UNITS6.1 OverviewThis chapter explains how to install the SH80 hardware unitsnormally positioned in the wheel
Wheelhouse units47851--164300 / C6.2 LocationIntroductionOn board routines should be thoroughly discussed with the captainwhen selecting the locations
Simrad SH8048851--164300 / CDisplay unitThe display unit should be located so that it is best protected fromglare which reduces readability. I t may b
Wheelhouse units49851--164300 / C6.3 Display unitDifferent display units are available as optional equipment. Forinstallation and operation of the cho
Simrad SH8050851--164300 / C6.4 Sonar Operating PanelObserve the following procedure. To ensure correct operation, tickoff every item when the action
Wheelhouse units51851--164300 / C6.5 Sonar Processor Unit (MC70)The MC70 Sonar Processor Unit should be mounted on the deckor shelf inside a console,
Simrad SH8052851--164300 / C6.6 Sonar Interface UnitThe Sonar Interface Unit should be mounted vertically with thecable inlet downwords on a side wall
Cable layout and connections53851--164300 / C7 CABLE LAYOUT7.1 IntroductionThis chapter describes the installation requirements for SH80system wiring.
Installation manualIII851-164300 / CTable of contents1 INTRODUCTION 1...1.1 Purpose and description 1...
Simrad SH8054851--164300 / C7.2 System cablingCable layoutCables are identified according to individual cable numbers anddrawing numbers listed on the
Cable layout and connections55851--164300 / C115 / 230 Vac mains C1115 / 230 Vac mains C3*C18* AC MainsSonar Processor UnitOperating PanelDisplay Unit
Simrad SH8056851--164300 / C7.3 Cable specificationsThe list below specifies each cable used on the SH80 sonar.References are made to detailed cable d
Cable layout and connections57851--164300 / CC11-C14 / C20-C25 Peripheral equipmentThese are cables used to interface peripheral equipment. They arede
Simrad SH8058851--164300 / C7.4 Wheelhouse cablingIntroductionConnections to the Sonar Processor Unit are made on theconnectors on the rear side of th
Cable layout and connections59851--164300 / CConnectionsThe illustrations below identify the main connectors on the SonarProcessor Unit and the Sonar
Simrad SH8060851--164300 / CCablesC1 - AC Power to the Display UnitThis is a standard mains supply cable. It is included in the deliverywith the optio
Cable layout and connections61851--164300 / C2 Secure the plug on the r ear side of the Sonar Processor Unitwith the bracket.If the delivered cable co
Simrad SH8062851--164300 / C→ Cable details on page 168.Observe the following procedure for the connection of the USBdata cable.1 Connect the quadrati
Cable layout and connections63851--164300 / C1 Run the 100 m data cable from the wheelhouse and down tothe sonar room.Note The data cable from the whe
Simrad SH80IV851-164300 / C2 INSTALLATION PLANNING 23...2.1 General 23...2.2 L
Simrad SH8064851--164300 / C7.5 Sonar room cablingIntroductionAll sonar room cabling must be performed as specified. The cablenumbers used to identify
Cable layout and connections65851--164300 / C2 Terminate the cable shielding.→ Cable s hielding is shown in figure 23.Cablemainscreen(CD3117)Figure 23
Simrad SH8066851--164300 / CFigure 24 Connections tothe Motor Control UnitC19C17REMOTES 302HOIST STOPLOWERHAND CRANKS 303(CD5821)CablestripE30
Cable layout and connections67851--164300 / CUse the following procedure for connecting the cable C15 to theTransceiver Unit. To ensure correct operat
Simrad SH8068851--164300 / CC18-ACpowertotheTransceiverUnitThis cable is included in the delivery. It is used for the mains supplyto the Transceiver U
Cable layout and connections69851--164300 / CC16 - Transducer cableThe transducer cables are provided by the manufacturer. They arephysically connecte
Simrad SH8070851--164300 / C7.6 Basic cabling requirementsCable traysAll permanently installed cables associated with the system mustbe supported and
Cable layout and connections71851--164300 / CRadio Frequency interferenceAll cables that are to be permanently installed within 9 m (30 ft)of any sour
Simrad SH8072851--164300 / CMetallic casings, pipes and conduits must be grounded, and whenfitted with joints these m ust be mechanically and electric
Connecting peripheral equipment73851--164300 / C8 PERIPHERAL EQUIPMENT8.1 GeneralIntroductionIt is not necessary to make the connection of the periphe
Installation manualV851-164300 / CIntroduction 47...Distances 47...
Simrad SH8074851--164300 / CPhysical connections to the Sonar Interface UnitThe figure below shows the positions for the different auxiliaryconnection
Connecting peripheral equipment75851--164300 / C8.2 Speed log connectionOverviewThe sonar can read the speed information from one of thefollowing thre
Simrad SH8076851--164300 / CSpeed log with RS-232 outputThe sonar can also read the speed log data from a RS-232 serial linewith a standard NMEA 0183
Connecting peripheral equipment77851--164300 / C8.3 Course gyro connectionOverviewThe SH80 sonar can read the course information from an RS-232serial
Simrad SH8078851--164300 / C8.4 (D)GPS connectionA (D)GPS may be connected to the SH80 sonar to indicate thelatitude and l ongitude position of the ve
Connecting peripheral equipment79851--164300 / C8.5 Echo sounder connectionTo provide depth i nformation on the sonar, an echo sounder withstandard NM
Simrad SH8080851--164300 / C8.6 Trawl system connectionThe SH80 sonar can read the trawl data from a Simrad FS Trawlsonar or ITI (Integrated Trawl Ins
Connecting peripheral equipment81851--164300 / C8.7 Purse seine system connectionTo provide purse seine depth information on t he sonar’s display,Simr
Simrad SH8082851--164300 / C8.8 Current meterThe SH80 sonar can read the data from the following current metersystems:• Kaijo DCG-200The interface is
Connecting peripheral equipment83851--164300 / C8.9 Radio buoysThe SH80 sonar can read the data from one of the following GPSbased radio buoy systems:
Commenti su questo manuale