Setting up the second Remote sensor
1 Connect the second Remote sensor to the PI Configurator.
2 Press Establish communication with Sensor.
- Observe that the current sensor conf iguration
parameters are displayed in the message field.
3 Use the spin box next to the Number label to define the
sensor’s number in the Twin Spread system.
- The number you choose MUST match the other
number chosen in step 5 in the Twin Spread sensor
setup.
4 Press the Configure sensor button to upload the new
parameters.
5 Press Terminate communication, and disconnect the
sensor.